Cabinet sizes are mostly fixed in depth and height and variable in width. Base units run 150–900 mm wide at 600 mm deep; wall units 300–1,000 mm wide at 300–350 mm deep; tall units are 600 mm wide and 2,100–2,400 mm high. The width is where the design lives, and where custom cost starts.
Base widths run 150–900 mm, with 600 mm the most common.
Wall widths run 300–1,000 mm at 300–350 mm deep.
Drawer cabinets run 300–900 mm; above 900 mm they are usually split.
Blind corners use a 900 × 900 mm footprint.
Custom widths cost more; standard widths cost less and ship faster.
1. Base cabinets
| عرض | الاستخدام النموذجي | Door or drawer |
|---|---|---|
| 150 – 300 مم | Spice, tray, pull-out | Single door or pull-out |
| 400 – 500 مم | Narrow base, bin | باب واحد |
| سماكة 600 ملم | Standard base, drawer stack | Single door or 3 drawers |
| 700 – 800 مم | Sink, hob | باب مزدوج |
| سماكة 900 ملم | Wide drawer, corner | Double door or 2 drawers |
600 mm is the workhorse. Most kitchens are a mix of 600 mm units plus a few narrow or wide units to close the run. A run that is all custom widths is a design choice, not a necessity.
2. خزائن الحائط
| عرض | الاستخدام النموذجي | منتجات الأبواب |
|---|---|---|
| 300 – 400 مم | Narrow wall, spice | باب واحد |
| 500 – 600 مم | جدار قياسي | باب واحد |
| 700 – 800 مم | جدار مزدوج | باب مزدوج |
| 900 – 1,000 مم | Wide wall, plate storage | باب مزدوج |
Wall cabinets above 600 mm usually need double doors, because a single door that wide is heavy and swings too far.
3. Tall cabinets
Tall units are 600 mm wide and 2,100–2,400 mm high, with 2,400 mm the common height for a full-height larder. Widths of 600 mm fit ovens and fridge housings; 900 mm fits a fridge and a larder side by side. Confirm appliance dimensions before fixing the width.
4. Drawer cabinets
Drawer widths run 300–900 mm. A 600 mm drawer is the standard; 900 mm is the practical maximum before the box needs heavier runners and the face starts to flex. Deep drawers for pots are usually 600 mm wide and 500 mm deep.
5. Corner and sink cabinets
| النوع | البصمة | ملاحظات |
|---|---|---|
| زاوية عمياء | شنومكس × شنومك مم | Carousel or pull-out recovers space |
| L-shape corner | شنومكس × شنومك مم | Two runs meet |
| قاعدة حوض الغسيل | 800 – 1,200 مم | Depends on sink size |
| Hob base | 600 – 900 مم | Depends on hob |
Corner cabinets are where the layout and the cabinet schedule must agree. A 900 mm corner with a 600 mm door leaves 300 mm blind, which is why carousel fittings exist.
6. Standard versus custom
Standard widths cost less because the factory amortises setup across many units. Custom widths are normal on projects, but each one adds cost and lead time. Use standard widths where the design allows and reserve custom widths for the places that matter. The دليل الأبعاد covers depth and height.
7. Reading a size schedule
A size schedule should list type, width, height, depth and door configuration for every unit. If it lists only widths, the heights and depths are being assumed, which is where errors enter. Check the schedule against the appliance list before release.
8. Common sizing mistakes
Three mistakes recur: using a 600 mm base where a 500 mm would close the run, forgetting the filler at the wall, and specifying a 900 mm drawer without checking the runner rating. Each is cheap to fix on paper and expensive on site.
9. قائمة مراجعة قبل الالتزام
قبل التوقيع، تأكد من ستة أمور: جودة اللوحة، طراز الجهاز، نظام التشطيب، معيار التعبئة، نطاق الفحص، وجدول الدفع. يجب توثيق كل منها كتابيًا، وليس عبر مكالمة هاتفية. تُحوّل قائمة التحقق من عرض الأسعار هذه الأمور الستة إلى مقارنة موجزة في صفحة واحدة.
10. الأخطاء الشائعة
الخطأ الأكثر شيوعًا هو مقارنة سعر المصنع بالتكلفة النهائية بعد الشحن. ثانيًا، إغفال تكلفة الفحص في الميزانية. ثالثًا، دفع المبلغ المتبقي قبل الموافقة على الفحص. يمكن تجنب كل هذه الأخطاء بتحديد نطاق العمل كتابيًا وإجراء فحص ما قبل الشحن.
11. كيفية قياس الغرفة
قِس كل جدار عند ثلاث نقاط: الأعلى، والوسط، والأسفل، واستخدم أصغر قياس. نادرًا ما تكون الجدران مربعة تمامًا، وانحناء بمقدار ١٠ ملم على امتداد ثلاثة أمتار يُغيّر نوع الحشو. قِس السقف عند كل زاوية، وسجّل مواقع المقابس الكهربائية، والمشعات، وأنابيب الصرف الصحي قبل الرسم. يوفر المسح الدقيق وقتًا أطول من الرسم السريع، ويحتوي دليل القياس على ورقة قابلة للطباعة.
الأسئلة المتكررة
What is the most common base cabinet width?
600 mm (24 in). It fits a single door or a drawer stack and works with most standard appliances.
How wide can a drawer cabinet be?
300–900 mm. Above 900 mm the drawer box needs heavier runners and the face can flex, so wide drawers are usually split.
What size is a blind corner cabinet?
900 × 900 mm is the common footprint, with a 600 mm door and a blind panel. Carousel or pull-out fittings recover the lost corner.
How wide should a sink base be?
800–1,200 mm depending on the sink. A 600 mm sink needs at least an 800 mm cabinet to leave room for the tap and waste.
Can wall cabinets be deeper than 350 mm?
Yes, but they project over the worktop and reduce headroom. Above 350 mm, consider a tall unit instead.
Do cabinet widths have to be standard?